Home Improvement

Range Hood Size: How Wide and How Many CFM You Need

Range Hood Size: How Wide and How Many CFM You Need

A hood that looks right in the showroom can fail badly over a real stove. Smoke rolls past the edges, grease films the upper cabinets, and the fan roars without clearing the air. Getting the range hood size right means solving three numbers at once: width, depth and airflow measured in cubic feet per minute (CFM). The short answer is that the hood should be at least as wide as your cooktop, ideally 3 inches wider on each side, and should move roughly 100 CFM for every 10,000 BTU of gas burner output or about 10 CFM per inch of width for an electric range against a wall.

Those two rules cover most kitchens. The details change when you cook on gas, when the cooktop sits in an island, when the ceiling is unusually high, or when the kitchen is small enough that a big fan would be overkill. Each of those situations is covered here, along with the depth and mounting height that make the width and CFM actually work together.

How to Choose the Right Range Hood Size

Start with the cooktop, not the cabinet opening. Measure the outside width of the range or cooktop from edge to edge. Standard residential ranges come in 30 inch and 36 inch widths, with professional style units at 48 and 60 inches. Your hood should never be narrower than that number. A hood that matches the cooktop exactly will work over an electric range on a wall, but adding width gives the hood a bigger capture area so rising steam and smoke have nowhere to escape.

Typical pairings look like this:

Cooktop width Minimum hood width Better hood width
24 in 24 in 30 in
30 in 30 in 36 in
36 in 36 in 42 in
48 in 48 in 54 in
60 in 60 in 66 in

Range hood width is the number most people shop by, and it matters most because cooking plumes expand as they rise. By the time vapor reaches a hood 30 inches above the burners, it has spread several inches beyond the pan. That is why the extra 3 inches per side is such a reliable upgrade, especially over a front burner where a tall stockpot or a searing skillet throws heat outward.

Extra Overhang for Gas Ranges

Gas burners produce more heat, more moisture and combustion byproducts that electric and induction cooktops do not. Hot air rises faster and wider, so gas cooks benefit from the full 6 inches of extra width. For a 30 inch gas range, a 36 inch hood is a smart choice. For a 36 inch professional style gas range with high-output burners, a 42 inch hood is worth the extra wall space if your cabinets allow it.

Island Hoods Need More Width

An island hood has no back wall to guide the plume. Cross drafts from windows, doorways and people walking by push smoke sideways, so island installations should overhang the cooktop by at least 3 inches on every side, and many designers go 6 inches wider overall in both directions. Island hoods also need more airflow than a wall hood over the same range, usually 50 to 100 percent more.

Depth: The Dimension People Forget

Range hood dimensions include depth, and a shallow hood can underperform even when the width is perfect. The front burners on most ranges sit 20 to 24 inches from the wall. A hood that is only 17 or 18 inches deep leaves the front pans uncovered, and that is exactly where most searing and sauteing happens.

  • Under-cabinet hoods: typically 18 to 22 inches deep. Choose the deeper end if you cook on the front burners often.
  • Wall chimney hoods: usually 19 to 24 inches deep, with professional styles reaching 27 inches.
  • Island hoods: often 24 to 27 inches deep, since they need to cover the whole cooktop from above with no wall support.

A good target is a hood that covers at least half of the front burners, and ideally reaches to the front edge of the cooktop. If you can only stretch one dimension, deeper often beats wider for a wall-mounted unit.

Mounting Height and How It Changes Size

Most hoods are designed to sit 24 to 30 inches above an electric cooktop and 27 to 33 inches above a gas range. Always check the installation manual for your specific model, since manufacturers set minimum clearances for fire safety and maximum heights for capture performance. The higher a hood hangs, the wider the plume is when it arrives, and the more width and CFM you need to catch it.

If your ceiling is tall and you want the hood mounted at 36 inches for sightlines, step up one width size and add 10 to 20 percent more airflow. Chimney extensions are available for most wall and island hoods so the duct cover reaches ceilings of 9 or 10 feet without leaving a gap.

How Many CFM You Need

Airflow sizing has two common methods. Use whichever gives the larger number, then adjust for your duct run.

By BTU for Gas Ranges

Add up the maximum BTU rating of every burner. Divide by 100. A range with four 15,000 BTU burners totals 60,000 BTU, so it calls for about 600 CFM. High-output professional ranges with 80,000 to 100,000 BTU combined can push recommendations past 800 CFM, which raises the question of makeup air.

By Width for Electric and Induction

Multiply the cooktop width in inches by 10 for a wall installation. A 30 inch electric range needs roughly 300 CFM, a 36 inch unit about 360 CFM. For an island, multiply by 15 instead, so a 36 inch island cooktop needs around 540 CFM.

Adjust for Ductwork

Fan ratings assume ideal conditions. Every elbow, long horizontal run and roof cap adds resistance and lowers real airflow. As a rough rule, add about 25 CFM for each 90 degree elbow and a little extra for runs longer than 10 to 15 feet. Use the duct diameter the manufacturer specifies, commonly 6 inches for hoods around 400 CFM and 8 to 10 inches for higher outputs. Undersized duct is one of the most common reasons a large range hood sounds loud and performs poorly.

Makeup Air and Large Hoods

A powerful fan pulls a lot of air out of a tight modern house. That air has to come from somewhere, and if it comes back down a water heater flue or fireplace chimney, combustion gases can spill into the living space. Many local codes require a makeup air system once a hood exceeds about 400 CFM. Check with your building department before buying a hood above that level, and plan the makeup air damper into the budget. In practice, many home cooks find that 400 to 600 CFM with good width and depth outperforms a 1,000 CFM fan on an undersized hood.

Range Hood for a Small Kitchen

Compact kitchens, condos and apartments often have a 24 inch or 30 inch range and limited ducting options. A range hood for small kitchen spaces still follows the same width rule, but airflow needs drop. A 24 inch electric cooktop can be handled by a 250 to 300 CFM under-cabinet hood. Because small rooms hold less air, an oversized fan will also make the space feel drafty and noisy.

  • Choose a hood one size wider than the range if the cabinets allow it, such as a 30 inch hood over a 24 inch range.
  • Look at slim insert or under-cabinet styles that tuck behind a cabinet face to save visual bulk.
  • If you cannot vent outside, a recirculating hood with charcoal filters will capture grease and some odor, but it will not remove heat or moisture. Replace the charcoal filters every 3 to 6 months.
  • Check the sone rating. Something around 1 to 3 sones on the low setting keeps conversation comfortable in a tight space.
Looking to buy Range Hood Size? Compare top-rated options.
Shop on Amazon →Browse Our Shop
As an Amazon Associate we earn from qualifying purchases.

Picking a Style That Fits the Size

The style of hood affects which kitchen hood sizes are available, and sometimes it limits the range hood size you can install at all. Under-cabinet hoods are limited by the cabinet opening, usually 30 or 36 inches. A wall mount range hood with a chimney cover offers more freedom, since it can be wider than the cabinets beside it and comes in deeper profiles. Island hoods require ceiling structure strong enough to carry them, which can mean adding blocking between joists. Custom wood or plaster hoods built around a fan insert let you set any width you want, as long as the insert itself is sized for your cooktop and the canopy above it is at least as wide.

Large range hood designs over 48 inch ranges often use two fan motors or a remote blower in the attic or on an exterior wall. Remote blowers reduce noise in the kitchen and are worth considering for any setup above 900 CFM.

Installation Steps for Sizing and Fit

  1. Measure cooktop width, depth from the wall to the front burner centers, and ceiling height.
  2. Calculate CFM by BTU or by width, then add for elbows and long runs.
  3. Choose a hood width equal to the cooktop at minimum, 6 inches wider for gas or island setups.
  4. Confirm the mounting height in the manufacturer’s manual and confirm the chimney cover reaches your ceiling.
  5. Plan the duct path to the exterior with the fewest bends and the correct diameter. Never terminate a duct in an attic or wall cavity.
  6. Check whether your local code requires makeup air for the airflow you selected.
  7. Turn off the breaker feeding the hood circuit and confirm power is off with a non-contact voltage tester before connecting any wiring.

Electrical Safety for Hood Installation

Many hoods plug into an outlet inside the cabinet, while others are hardwired to a junction box. Either way, turn off the breaker and confirm power is off with a non-contact voltage tester before you touch any wires. Never test or work on energized conductors. If the location has no existing circuit or outlet, adding one is a job for a licensed electrician, who will also make sure the circuit is sized for the fan and any built-in lighting. Hoods with remote blowers or integrated makeup air dampers often need additional wiring, which is another reason to bring in a pro.

Troubleshooting a Hood That Does Not Keep Up

  • Smoke escapes at the front: the hood is too shallow or mounted too high. A deeper hood or lower mounting usually fixes it.
  • Smoke escapes at the sides: the hood is too narrow, especially common with gas ranges. Upgrade one width size.
  • Loud fan, weak suction: duct is undersized, crushed, or has too many elbows. Check the backdraft damper for sticking too.
  • Grease on upper cabinets: clean or replace filters monthly with heavy use, and confirm the hood covers the front burners.
  • Doors whistle or the pilot flickers when the fan runs: the house is starved for air. This is a makeup air problem and should be addressed promptly.

Cost Ranges

Basic under-cabinet hoods in 30 and 36 inch widths typically run a few hundred dollars. Wall chimney hoods range from the mid hundreds to a couple thousand dollars depending on width, finish and motor quality. Island hoods and professional styles commonly start around a thousand dollars and can climb well past that for 48 inch and wider models. Professional installation varies with the duct run, often several hundred dollars for a straight swap and more if new ductwork, roof penetrations, electrical work or makeup air are involved.

When to Call a Pro

Swapping a same-size under-cabinet hood on an existing duct and outlet is a manageable DIY job for many homeowners. Call a contractor when you are adding a new exterior penetration through the roof or wall, installing an island hood that needs ceiling blocking, upsizing above 400 CFM where makeup air may be required, or adding a new circuit. A licensed electrician handles new wiring, and an HVAC contractor can design and install makeup air systems correctly.

Frequently Asked Questions

Should a range hood be wider than the stove?

Ideally yes. A hood the same width as the stove works over an electric range on a wall, but 3 inches of overhang on each side catches more smoke and steam. Gas ranges and island cooktops benefit most from the extra width.

What size range hood do I need for a 30 inch stove?

A 30 inch hood is the minimum and a 36 inch hood is better, especially for gas. For airflow, aim for about 300 CFM over a 30 inch electric range or 100 CFM per 10,000 BTU over gas.

Is 600 CFM too much for a home kitchen?

Not for a gas range with high-output burners, but many codes require makeup air above about 400 CFM. For most electric ranges on a wall, 300 to 400 CFM is plenty when the hood is the right width and depth.

How deep should a range hood be?

Aim for a hood that covers at least half of the front burners, which usually means 20 to 24 inches for wall hoods. Island hoods are often 24 to 27 inches deep.

How high should a range hood be above the cooktop?

Most manufacturers recommend 24 to 30 inches above electric cooktops and 27 to 33 inches above gas. Follow your model’s manual, and size up width and airflow if you mount it higher.

What size range hood fits a 36 inch range?

A 36 inch range needs a hood at least 36 inches wide, and a 42 inch hood is better for gas or professional style ranges. For airflow, a 36 inch electric range on a wall needs about 360 CFM, while a gas range should be sized by total burner BTU divided by 100. Island installations need more width and airflow than wall hoods.

What size duct does a range hood need?

Use the duct size the hood’s manual specifies, which is commonly 6 inch round duct for hoods around 400 CFM and 8 to 10 inch duct for higher outputs. Never reduce the duct below the hood’s outlet size, since a smaller duct chokes airflow and makes the fan louder. Keep runs short, with as few elbows as possible, and vent to the outdoors, not into an attic.

What is the smallest range hood size?

The smallest standard range hoods are about 20 inches wide, made for compact 20 inch ranges in apartments and small kitchens. The 24 inch hood is the more common small size. Whatever the size, the hood should be at least as wide as the cooktop, so measure the range edge to edge before shopping rather than going by the cabinet opening.

How do you find the right range hood filter size?

Measure the existing filter’s length, width, and thickness, or find the model number on the label inside the hood and look up the matching filter. Filter sizes are not universal, so a filter for one brand or model may not fit another. Aluminum mesh and stainless baffle filters can be washed, while charcoal filters in recirculating hoods must be replaced.