A powerful range hood is only as good as the duct behind it, and most people never think about that duct until the kitchen keeps filling with smoke. The range hood vent duct carries grease-laden air and moisture out of your home, and if it is undersized, too long, or full of restrictive elbows, even an expensive hood cannot move the air it is rated for. Getting the range hood vent duct right means matching the duct diameter to the hood, keeping the run short and smooth, using the correct material, and terminating it properly outside. This guide walks through each of those decisions so your hood actually clears the air.
Part of our Kitchen Remodeling guide — explore the full guide →
Why the Duct Matters More Than the Hood
Homeowners obsess over a hood’s rated airflow in cubic feet per minute, or CFM, but a hood almost never achieves its rated CFM through a poorly designed duct. Every foot of duct, every elbow, and every reduction in diameter adds resistance, called static pressure, that the blower must fight. Choke the duct and a 600 CFM hood might move a fraction of that, leaving grease and steam to coat your cabinets and haze your windows.
Think of the duct as the hood’s lungs. A ducted hood that vents to the outside is far more effective than a ductless, recirculating hood that just filters air through charcoal and blows it back into the kitchen. If you cook seriously and can vent outside, always choose a ducted setup and give it a properly sized, well-routed duct. The hood and the duct are one system, and the duct is the part people botch.
Sizing the Duct Diameter
Duct diameter must match the hood’s requirement, and bigger hoods need bigger ducts. As a general guide, hoods up to around 400 CFM often use a 6 inch round duct, hoods in the 400 to 600 CFM range typically call for 7 or 8 inches, and high-output hoods of 600 to 900 CFM or more need 8 to 10 inches. Always follow the specific hood manufacturer’s minimum duct size, since undersizing throttles performance and can void the warranty.
Never reduce the duct below the hood’s outlet size to fit a smaller opening, a common shortcut that cripples airflow. If you must transition from a rectangular hood outlet to round duct, use a smooth transition fitting sized to maintain the equivalent area. Round duct flows better than rectangular for the same area because it has less surface resistance, so prefer round where the run allows.
Duct Material and What to Avoid
Use rigid, smooth-wall metal duct, either galvanized steel or, for high heat and grease, sometimes stainless. Rigid metal is smooth inside, which minimizes airflow resistance and does not trap grease the way ridged surfaces do. Avoid flexible plastic and, critically, do not use flexible foil dryer-style duct for a range hood; its corrugated interior kills airflow and its accordion ridges collect grease, which is both a performance and a fire concern.
Seal duct joints with the appropriate metal-duct tape or approved sealant so grease-laden air does not leak into wall or ceiling cavities. Where the duct passes through unconditioned space like an attic, insulating it reduces condensation, since warm, moist kitchen air hitting cold metal drips water back down the run. The goal is a smooth, sealed, rigid metal path from hood to exterior with as little grease-trapping surface as possible.
Keep the Run Short and the Turns Gentle
Length and bends are the silent killers of hood performance. The shorter and straighter the duct, the better the hood breathes. Every 90 degree elbow adds resistance equivalent to several feet of straight duct, so minimize elbows and, where you must turn, use two 45 degree bends or a long-radius elbow instead of a tight 90 where possible. Plan the route to take the most direct path to the outside, whether straight up through the roof or straight back through an exterior wall.
Many hood manufacturers publish a maximum equivalent duct length that accounts for elbows, and staying under it is essential. As a planning habit, count each 90 degree elbow as adding roughly the manufacturer’s stated equivalent length and keep the total within spec. A wall-mounted hood on an exterior wall with a short horizontal run is the easiest to vent; an island hood that must run up and across the ceiling is the hardest and needs the most careful sizing.
Terminating Outside Correctly
The duct must end outside the house, never in the attic, soffit, or crawl space, where dumping greasy, moist air causes moisture damage, mold, and a grease buildup that is a genuine hazard. Terminate with a proper exterior wall cap or roof cap made for kitchen exhaust, fitted with a backdraft damper that opens when the hood runs and closes to keep out cold air, rain, and pests. Some caps include a bird screen, but avoid fine mesh that clogs with grease and restricts flow.
Position a wall termination away from windows and doors so odors do not blow back inside, and keep it clear of soffit vents that would suck the exhaust into the attic. On a roof, use a dedicated grease-rated roof cap and flash it properly to keep the roof watertight, which is a task worth handing to a roofer if you are not comfortable with roof penetrations. A correct termination is what turns all your duct work into air that actually leaves the building.
Makeup Air, Codes, and When to Call a Pro
Powerful hoods pull a lot of air out of the house, and that air has to come from somewhere. High-CFM hoods, often those above a certain threshold set by local code, require a makeup air system that introduces replacement air, both for performance and to prevent backdrafting of other combustion appliances like a furnace or water heater. Backdrafting can pull carbon monoxide into the home, so this is a safety matter, not just an efficiency one. Check your local code for the makeup air threshold.
Because ducting interacts with structure, roofing, and combustion safety, plan the route carefully and follow both the hood manufacturer’s instructions and local building code. A confident DIYer can install a straightforward wall-vented duct, but complex routing, roof penetrations, makeup air, or any concern about combustion appliances is best handled by a professional. Get the duct right and even a modest hood will clear smoke and steam effortlessly; get it wrong and no amount of CFM will save your kitchen.
Routing Options for Different Hood Locations
Where your hood sits dictates the easiest duct path. A wall-mounted or under-cabinet hood on an exterior wall has the simplest run: straight back through the wall to a termination cap outside, often only a foot or two of duct. That short, direct path is why exterior-wall hoods perform so well and are the easiest to install. When the hood sits on an interior wall, the duct usually has to turn upward and travel through the wall or a cabinet soffit into the attic, then out through the roof, adding length and elbows that must be sized for.
Island and ceiling-mounted hoods are the most demanding. Their duct must rise through the ceiling and cross the attic or joist space to reach an exterior wall or roof cap, which means a longer run with more turns. For these installations, size the duct at the larger end of the hood’s allowable range and keep the routing as direct as possible, because the extra length eats into the hood’s effective airflow. Downdraft systems, which pull air down and out below the cooktop, have their own routing rules and often struggle against rising heat, so follow the manufacturer’s guidance closely if you choose one.
Maintenance That Keeps Airflow Strong
A duct is not install-and-forget, because grease slowly accumulates inside it and on the components. The hood’s own grease filters are your first line of defense; wash aluminum mesh filters regularly, roughly monthly for a busy kitchen, in hot soapy water or the dishwasher so grease is captured at the hood rather than passing into the duct. Clean filters also keep airflow strong, since a clogged filter chokes the hood as surely as an undersized duct does.
Check the exterior termination cap and its backdraft damper periodically. Grease and debris can gum up the damper so it fails to open fully or fails to close, letting in cold air and pests. Wipe it clean and confirm it swings freely. In a heavy-cooking household, having the duct interior inspected and cleaned over time reduces both airflow loss and the fire risk that grease buildup represents. A well-maintained system that started with correct sizing, smooth rigid metal duct, minimal elbows, and a proper exterior termination will pull smoke and steam out of your kitchen reliably for the life of the hood, keeping your cabinets, walls, and air noticeably cleaner.