A garage door weighs between 130 and 350 pounds, and when it refuses to move you are suddenly staring at the single heaviest moving object in your home. The good news is that a garage door not opening is usually caused by one of a handful of simple problems you can diagnose and fix yourself in under an hour. The bad news is that one of the possible causes, a snapped torsion spring, is genuinely dangerous and belongs to a professional. This guide sorts the easy fixes from the ones worth paying for.
Part of our Garage Doors guide — explore the full guide →
Work through the checks below in order. They run from cheapest and safest to most involved, so you fix the likely culprit first without taking anything apart unnecessarily.
- Start With the Simple Power and Remote Checks
- Check the Photo-Eye Safety Sensors
- Look for a Broken Torsion Spring
- Test the Manual Release and Track Alignment
- When the Opener Motor Runs but Nothing Moves
- When to Call a Professional
- Preventing the Next Failure
- Cold Weather and Other Seasonal Culprits
- Frequently Asked Questions
Start With the Simple Power and Remote Checks
Before you assume the worst, rule out the boring stuff. A surprising share of service calls end with the technician simply plugging the opener back in.
- Dead remote battery: Try the wall-mounted button. If the door opens from the wall but not the remote, replace the remote’s coin-cell battery, usually a CR2032.
- Unplugged or tripped opener: Check that the opener motor is plugged in and that the outlet has power. A tripped GFCI or breaker is common after a storm.
- Lock mode engaged: Many wall consoles have a “lock” or “vacation” button that disables remotes. If it was pressed accidentally, hold it down for a few seconds to release.
- Out-of-range or dead keypad: Exterior keypads run on their own battery and can lose their programming after a power blip.
Check the Photo-Eye Safety Sensors
Since 1993, every automatic opener sold in the US has two photo-eye sensors mounted about six inches off the floor on each side of the door. If their infrared beam is broken or misaligned, the door will refuse to close, and many openers will also refuse to open normally or will reverse partway.
Look at the small LED on each sensor. A steady green or amber light on both means they are aligned. A blinking or dark light means trouble. Wipe the lenses with a soft cloth to clear cobwebs and dust, clear any object blocking the beam, and gently nudge the brackets until both lights glow steady. A loose bracket that lets a sensor droop is one of the most common reasons a door quits working.
Look for a Broken Torsion Spring
If the opener motor runs and strains but the door barely lifts, or if you hear a loud bang from the garage like a firecracker followed by a dead door, you likely have a broken spring. The torsion spring mounted on the shaft above the door does almost all the lifting; the motor only guides the door. A single spring lasts roughly 10,000 cycles, about seven to ten years for an average family.
Inspect the spring above the door. A broken one shows an obvious two-inch gap where the coil separated. Do not attempt to replace a torsion spring yourself. These springs store enormous energy and have caused serious injuries. A professional replacement runs $150 to $350, and it is money well spent. If you have two springs, replace both at once since the second is near the end of its life too.
Test the Manual Release and Track Alignment
Every opener has a red emergency release cord hanging from the trolley. Pull it to disconnect the door from the opener, then try lifting the door by hand. A properly balanced door should glide up smoothly and stay open about halfway on its own.
If the door is stuck or drags:
- Inspect the metal tracks on both sides for dents, bends, or gaps. A track knocked out of alignment by a bumped car will bind the rollers.
- Check the rollers for cracks or flat spots. Worn nylon rollers cost about $5 each and are easy to swap.
- Look for debris, hardened grease, or a stray object jamming the track.
- Lubricate the rollers, hinges, and springs with a garage-door-specific silicone or lithium spray, never WD-40, which attracts grit.
Remember to re-engage the trolley afterward by pulling the release cord toward the door or running the opener until it clicks back in.
When the Opener Motor Runs but Nothing Moves
If you hear the motor humming but the door doesn’t budge and the springs are intact, the problem is often inside the opener itself. A stripped trolley carriage, a broken drive gear, or a snapped chain or belt will let the motor spin without transmitting force. The plastic main drive gear on chain-drive openers is a frequent failure point and costs about $20 to $40 in parts, though replacing it takes some patience.
You may also see the opener’s travel limits knocked out of adjustment, which makes the door stop short or reverse. Most openers have adjustment screws or buttons to reset the open and close limits; consult your model’s manual for the exact procedure.
When to Call a Professional
Draw a clear line. Handle these yourself: batteries, sensor cleaning and alignment, lubrication, roller swaps, and minor track adjustments. Call a pro for anything involving the torsion or extension springs, cables that have frayed or come off the drums, badly bent tracks, or a door that has come off its tracks entirely. The cables and springs are under extreme tension, and a slip can cost you fingers.
A typical service visit for spring or cable work runs $150 to $350, while a full opener replacement lands around $250 to $600 installed. Weigh the repair cost against the opener’s age; if a 15-year-old unit needs a new gear, motor, and springs, a new belt-drive opener is quieter and comes with a fresh warranty.
Preventing the Next Failure
Most garage door failures are the result of skipped maintenance. Twice a year, lubricate all moving metal parts, tighten the lag bolts and roller brackets that vibrate loose, wipe the photo eyes, and run the balance test with the door disconnected. Listen for new grinding or scraping sounds, which are early warnings. Ten minutes of upkeep every six months keeps a garage door not opening from turning into a morning you are trapped at home with a car you can’t reach.
Cold Weather and Other Seasonal Culprits
Winter brings its own set of problems that catch homeowners off guard. Grease in the tracks and rollers thickens in freezing temperatures, making the door drag or stall. Rubber weather seals at the bottom of the door can freeze to the concrete, so when the opener tries to lift, the motor strains against a door glued to the ground and reverses or gives up. Many openers also have a temperature-sensitive force setting that trips in the cold, sensing extra resistance and shutting down as a safety measure.
If your door only misbehaves on cold mornings, switch to a silicone-based lubricant that stays flexible in low temperatures, break any ice seal at the base before operating, and check whether your opener has a force adjustment you can nudge up slightly for winter. Just don’t over-crank the force, since that defeats the safety reversal feature that protects people and pets.
Frequently Asked Questions
Why does my garage door open but not close?
This is almost always the photo-eye safety sensors. When the infrared beam is blocked or the sensors are misaligned, the opener refuses to close as a safety measure and usually blinks a light or reverses. Clean the lenses, clear anything in the beam’s path, and realign the brackets until both indicator lights glow steady.
Can I open the door manually if the power is out?
Yes. Pull the red emergency release cord to disconnect the door from the opener, then lift by hand. A properly balanced door lifts easily. If it is extremely heavy or won’t stay up, do not force it, as that points to a broken spring, which is a job for a professional.
How much does a typical repair cost?
Simple fixes like batteries, sensor alignment, and roller swaps cost little to nothing beyond parts. Spring or cable replacement runs $150 to $350, a new drive gear about $100 to $200 installed, and a full opener replacement $250 to $600. Weigh repairs against the age of the unit before committing.