One hard freeze is all it takes to split a buried lateral line, crack a backflow preventer, or pop the diaphragm out of a zone valve. The fix is to winterize irrigation system components before the first night that drops into the mid-20s °F, and there are only three real ways to get the water out: open manual drain valves, rely on automatic drain valves, or blow the lines clear with compressed air. Which one you use depends on how your system was built, not on personal preference.

If your lines have manual drain valves at the low points, you open them and let gravity do the work. If the installer put in automatic drain valves, the system empties a little every time a zone shuts off, and you only need to close the main supply and bleed the pressure. If there are no drains at all, which is common on newer installs and on flat lots, blowing out the lines with air is the only way to get them close to dry.

Every method shares the same bookends: shut off the water supply first, then deal with the backflow preventer, the drip zones, and the controller last. Get those steps in the right order and a sprinkler system that took a weekend to install will come back in spring without a single leak.

How to Winterize Irrigation System Lines: Pick Your Method First

Walk the yard before you touch a valve. Look at the lowest corners of each zone and along the mainline for small valve boxes, often round and about 6 inches across. A box with a brass or plastic valve and a quarter-turn handle inside is a manual drain. A small spring-loaded fitting threaded into a tee at a low point, with gravel underneath, is usually an automatic drain valve. No boxes anywhere usually means the system was designed to be blown out.

Here is how the three approaches compare for a typical residential lawn sprinkler system:

Method Best for Main drawback
Manual drain Systems with drain valves at every low point Water trapped between high spots stays put
Automatic drain Systems built with spring-loaded drains Heads and mainline may still hold water
Blowout Any system, especially ones with no drains Needs a large compressor and careful pressure control

Many homeowners who winterize irrigation system lines in cold climates combine methods. They drain sprinkler system zones through manual or automatic valves, then finish with a quick blowout to push out what gravity missed. That belt-and-suspenders approach makes sense where the frost line runs deep and pipe sits shallow.

Tools and Materials You Will Need

  • Flat screwdriver or valve key for the main shutoff and backflow test cocks
  • Channel-lock pliers and a bucket for small drains
  • Work gloves and safety glasses (non-negotiable for a blowout)
  • Air compressor rated for high volume if you are blowing out lines; a small pancake compressor will not keep up
  • A sprinkler blowout adapter kit that threads onto the backflow or a dedicated blowout port, ideally with a ball valve and gauge
  • Foam pipe insulation or an insulated backflow cover for any above-ground plumbing
  • Painter’s tape and a marker to label valves and zones as you go

Step 1: Shut Off the Water and Relieve the Pressure

Find the irrigation shutoff. In most homes it sits in the basement, crawlspace, or a utility room where the sprinkler tap leaves the house plumbing; in warmer regions it may be in a box near the water meter. Turn it fully off. If there is a small bleed cap or stop-and-waste port on that valve, open it to drain the short pipe run between the shutoff and the outside wall.

Next, run one zone from the controller for a minute. With the supply off, the heads will sputter and stop, which confirms the water is truly off and knocks the pressure out of the mainline. Skipping this check is how people blow out a system that is still fed by the house supply.

Method 1: Manual Drain Valves

Manual draining is the simplest way to empty sprinkler system lines for winter, and it works well on sloped yards where the installer put drains at every true low point.

  1. Open the manual drain on the mainline first, usually located just downstream of the backflow preventer or at the far end of the main.
  2. Open each zone’s low-point drain. Expect water to trickle into the gravel sump for several minutes.
  3. Open the test cocks on the backflow preventer to a 45-degree angle so the device can drain.
  4. Leave the drains open until spring. Water that seeps back in from groundwater will simply run out.
  5. Pull up and tip any heads that sit in low spots if water keeps standing in them.

The weakness here is geometry. Any pipe that dips and rises between two drains will hold a belly of water, and a check valve inside a head can trap water in the riser. On a gently rolling lawn that may be harmless; in a hard-freeze region it is a gamble.

Method 2: Automatic Drain Valves

A sprinkler system automatic drain valve is a small spring-loaded fitting that opens whenever line pressure falls below roughly 10 psi. Every time a zone closes, the valve dumps the water in that lateral into a gravel pocket. That makes winterizing almost passive.

  1. Close the main irrigation supply valve and open its bleed port.
  2. Run each zone briefly to relieve the pressure; the automatic drains will open and empty the laterals.
  3. Open the solenoid bleed screw on each zone valve, or loosen the solenoid a quarter turn, to let the water above the valve diaphragm drain.
  4. Drain the backflow preventer by opening its test cocks and any drain port.

Automatic drains only empty the pipe on the downstream side of the zone valve, and they only work if the gravel around them is not packed with silt. If a lawn stays soggy around one head all season, that drain is probably clogged or stuck open and should be replaced before you rely on it for another winter.

Method 3: Blowing Out the Lines With Compressed Air

Blowing out uses compressed air to push water out through the heads zone by zone. It is the most thorough of the three and the one most irrigation pros use in the snow belt. Because it gets its own detailed walkthrough, this overview covers only the essentials.

  • Volume matters more than pressure. A system needs enough cubic feet per minute to move water through a whole zone; a towable rental compressor is common for larger yards.
  • Keep pressure modest. Most residential PVC and poly systems should be blown out at about 50 psi for poly pipe and up to around 80 psi for rigid PVC. Check the lowest-rated component and stay under it.
  • Always keep a zone open. Turn a zone on at the controller before you open the air valve, and never blow air into a closed system.
  • Work in short cycles. Run each zone until mist replaces water, usually a couple of minutes, then move on and come back for a second pass. Dry pipe heats up from friction and can damage gears in rotor heads.
  • Never blow air through the backflow preventer. Connect downstream of it, and close its isolation valves before you start.

Wear safety glasses the entire time, keep people and pets away from heads, and never stand over a valve box while the system is pressurized. A fitting that lets go under air pressure can throw debris hard enough to injure you. If the compressor, fittings, or pressure numbers feel unfamiliar, this is the one method worth paying a technician to handle.

Looking to buy How to Winterize an Irrigation System? Compare top-rated options.
Shop on Amazon →Browse Our Shop
As an Amazon Associate we earn from qualifying purchases.

How to Winterize a Drip Irrigation System

Drip zones need different handling because emitters flow very little water and the tubing is thin. To winterize drip irrigation system lines, close the zone valve, then open the end caps or flush valves at the far end of each run and let the water drain out. Remove the filter bowl and pressure regulator, empty them, and bring them indoors where they will not crack. Many drip regulators and filters are rated for low pressure only, so if you blow out a drip zone, do it at very low pressure, generally 30 psi or less, and with the end caps open so air can escape.

Above-ground drip tubing will tolerate freezing better than PVC, but any water left in fittings can still split them. Draining and capping is enough in most yards.

Backflow Preventer and Controller Shutdown

The backflow preventer is often the most expensive single part of the system and the one most exposed to cold because it sits above ground. After draining, leave the test cocks open at a 45-degree angle, turn the isolation valves to half-open, and wrap the device with an insulated cover or foam. Do not seal it airtight with plastic; condensation trapped inside can cause its own problems.

At the controller, switch to the “off” or “rain” mode rather than unplugging it so the clock and programs stay saved. Owners winterizing a sprinkler system from any major brand will find the same basic option on most timers. If the controller is outdoors and has a backup battery, it can stay put; if it lives in an unheated garage that sees extreme cold, check the manual for storage temperature limits. These timers run on low-voltage 24-volt circuits to the valves, but the controller itself plugs into or is wired to a household circuit, so leave any hardwired connections alone.

Troubleshooting Common Winterizing Problems

  • Water keeps trickling from a drain. The main shutoff is leaking by. Tighten or replace it, or the lines will slowly refill.
  • A zone will not blow dry. A head with a check valve or a low spot is holding water. Run that zone longer in short bursts, or lift and tip the head.
  • Heads pop up but produce no air. The zone valve may not be opening. Check the controller wiring at the terminal strip and the solenoid.
  • Backflow preventer cracked last year. It was likely left with closed valves or water trapped in its body. Open the test cocks and isolation valves partially next time.
  • Spring startup leak at a fitting. Often a freeze split from a belly of water in the line. Consider adding a drain at that low spot during the repair.

Cost to Winterize Irrigation System Components

Doing it yourself with manual or automatic drains costs almost nothing beyond a backflow cover, which typically runs in the tens of dollars. A DIY blowout adds the compressor: renting a towable unit for a day often costs in the low hundreds, and a basic blowout adapter kit is modest. Professional winterization for a typical residential system of 4 to 8 zones generally falls in a moderate range, often $50 to $150 depending on region and zone count, with an extra fee for large properties. Compared with replacing a cracked backflow preventer or digging up a split mainline, which can run several hundred dollars or more, that service call is cheap insurance.

When to Hire an Irrigation Professional

Hire someone to winterize irrigation system parts for you if you do not know where your drains are, if the system has no drains and you do not have access to a high-volume compressor, or if the backflow preventer is a testable device that local rules require a certified tester to handle. It also makes sense when a mainline repair is needed or the shutoff valve inside the house will not close fully; that valve connects to your potable water supply, and plumbing work on it should follow local code, often by a licensed plumber. Many irrigation contractors bundle a fall winterization with a spring startup, which includes a check for leaks and broken heads.

Frequently Asked Questions

When should I winterize my sprinkler system?

Aim for the week before your area’s first expected hard freeze, which is usually a night at or below about 28 °F. A single light frost rarely damages buried pipe, but backflow preventers and above-ground plumbing are vulnerable much sooner.

Can I just drain the sprinkler system for winter instead of blowing it out?

Yes, if the system has drain valves at every low point and your ground does not freeze deeply. In colder regions or on flat lots, draining alone often leaves water in dips and heads, so a blowout is the safer finish.

Do automatic drain valves mean I do not need to winterize?

No. They empty the laterals, but you still need to shut off the supply, drain the backflow preventer, and relieve the zone valves. Clogged automatic drains also stop working without any visible sign.

How much air pressure is safe for a sprinkler blowout?

Most residential systems are blown out at around 50 psi for poly pipe and up to about 80 psi for PVC, and drip zones need far less. Always stay below the rating of your weakest component and keep a zone open while air is flowing.

Should I cover my backflow preventer in winter?

Yes. After draining it and leaving the test cocks partly open, wrap it with an insulated cover or foam. The cover slows cold exposure, though draining is what actually prevents a cracked body.