Extension cords cause more trouble from being too thin than from being too short. A 16-gauge cord that works fine for a string of lights can run hot behind a couch when someone plugs a power tool into it, and a 100-foot cord can starve a saw motor even when the gauge looks generous. An extension cord gauge chart solves both problems by matching the wire size (measured in AWG, where smaller numbers mean thicker wire) to the amps the tool draws and the length of the run.
The quick answer for most homes: 16 AWG for light loads up to about 10 amps on short cords, 14 AWG for loads up to about 13 to 15 amps at moderate lengths, and 12 AWG for 15-amp tools on long runs or heavy outdoor use. Ten-gauge cords handle the toughest jobs and long generator runs. Every figure here is a typical example. The cord’s own printed rating and the appliance’s nameplate govern, and some appliances should never go on an extension cord at all.
Extension Cord Gauge Chart by Amps and Length
Most cords carry a printed jacket marking such as “14/3 SJTW,” which tells you the gauge (14), the number of conductors (3, meaning hot, neutral and ground) and the jacket type. The table pairs common gauges with typical safe loads at different lengths for 120-volt use.
| Load (amps) | Up to 25 ft | 50 ft | 100 ft |
|---|---|---|---|
| Up to 10A | 16 AWG | 16 AWG | 14 AWG |
| 10 to 13A | 16 AWG | 14 AWG | 12 AWG |
| 13 to 15A | 14 AWG | 12 AWG | 10 AWG |
| 15 to 20A (20A cords) | 12 AWG | 12 AWG | 10 AWG |
Treat this as an extension cord amperage chart for typical conditions, not a guarantee. Manufacturers rate their own products, and a cord’s amp rating printed on the jacket or tag is the ceiling. When in doubt, go one gauge thicker. A heavier cord costs a little more and never hurts the tool.
Why Length Changes the Answer
Every foot of wire has a little resistance. Push current through a long, thin cord and some of the voltage gets lost as heat along the way. That loss is called voltage drop. A tool designed for 120 volts that only receives 110 volts at the end of a long cord works harder, draws more current, runs hotter and may wear out its motor early.
A practical target is keeping voltage drop around 3 to 5 percent. As a rough example, a 15-amp load on a 100-foot, 16-gauge cord can lose close to 10 volts, which is too much. The same load on a 100-foot, 12-gauge cord loses roughly 4 volts, which most tools tolerate well. That is the whole logic behind any extension cord sizing chart: as length goes up, gauge numbers must go down.
Joining two cords end to end creates one long cord with an extra connection that can loosen or heat up. Buy a single cord of the right length instead of daisy-chaining shorter ones.
Reading the Cord Jacket
The letters after the gauge describe how and where the cord can be used. Common codes include:
- S: service grade, meant for heavy use.
- J: junior service, rated for 300 volts instead of 600, common on household cords.
- T: thermoplastic jacket.
- E: elastomer jacket, which stays flexible in cold weather.
- O: oil-resistant outer jacket.
- W: rated for outdoor use, resistant to sunlight and moisture.
For yard work, look for a “W” marking, a lighted end that shows the cord is live, and a third grounding prong. A heavy-duty outdoor extension cord in 12 or 14 gauge covers most mowers, trimmers and pressure washers that plug in. Indoor-only cords (no W) should stay indoors, because their jackets can crack in sunlight and cold.
Also check for a certification mark from a recognized testing lab on the cord tag. Uncertified cords sold online sometimes use thinner copper than the printed gauge suggests.
Examples: Space Heaters, Power Tools and Generators
Space heaters
A typical 1,500-watt space heater draws about 12.5 amps for hours at a time. That steady, heavy load is exactly what overheats thin cords and loose power strip contacts. Nearly every heater manufacturer says to plug the heater directly into a wall outlet, and that is the safe rule. Keep at least 3 feet of clearance around the heater, use a model with tip-over and overheat shut-off, and never leave it running unattended or while sleeping unless the label allows. If the heater cord cannot reach an outlet, move the heater rather than adding a cord.
Power tools
Check the tool’s nameplate for amps. A 15-amp circular saw on a 50-foot cord needs 12 AWG; a 6-amp drill on a 25-foot cord is fine on 16 AWG. Miter saws, table saws and air compressors have high startup surge, so lean toward the thicker cord. If the tool bogs down or the cord feels warm, the cord is undersized.
Portable generators
Generators should run outdoors, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. That distance makes cord gauge important. For a 20-foot to 50-foot run carrying near 15 amps, 12 AWG is a sensible minimum; for longer runs or the 30-amp twist-lock outlet, use a cord made for that rating, typically 10 AWG. Never run a generator in a garage, basement or porch, even with the door open, and keep battery-backed carbon monoxide alarms on every level of the home. Feeding household circuits requires a transfer switch or interlock installed by a licensed electrician, never a cord plugged into a wall outlet.
Safe Use Habits
Reading an extension cord gauge chart correctly is only part of the picture. These habits prevent most extension cord fires and shocks:
- Uncoil fully. A coiled cord under load traps heat. Unroll a reel completely before running a heavy tool.
- Keep cords out of traffic. Never run cords under rugs, through doorways or under furniture, where the jacket can be crushed and heat cannot escape.
- Inspect before use. Discard cords with cracked jackets, exposed copper, bent or missing prongs, or melted ends. Do not tape over damage.
- Keep the ground prong. Never cut off the third prong or use a two-prong adapter to force a grounded plug into an old outlet.
- Use GFCI protection outdoors. Plug outdoor cords into a GFCI-protected outlet, especially near water, pools and wet grass.
- Do not use cords as permanent wiring. A cord stapled to a wall or run to a shed long-term is a sign you need a new outlet, which is a job for a licensed electrician.
- Plug big appliances into the wall. Refrigerators, window air conditioners, microwaves and space heaters should plug directly into a properly rated outlet.
Troubleshooting Common Cord Problems
The cord feels warm. Unplug it. Warmth along the length means the gauge is too thin for the load or the cord is coiled. Warmth at the plug alone usually means a worn outlet or a loose plug, which can arc.
The breaker trips when the tool starts. The tool’s startup surge plus other loads on the same circuit may exceed the breaker rating. Move to a less loaded circuit rather than a different cord.
The tool runs weak at the end of a long cord. Voltage drop is the likely cause. Switch to a thicker gauge or a shorter cord.
The plug is discolored or melted. Stop using the cord and the outlet. Turn off the breaker, confirm the outlet is dead with a non-contact voltage tester, and have an electrician check the receptacle. Never try to test voltage at the outlet while it is powered.
Typical Costs
As general ranges, light-duty 16-gauge indoor cords cost a few dollars to around $15. A 50-foot, 12-gauge outdoor cord commonly falls in the $30 to $70 range, and 100-foot, 10-gauge cords or generator cords can run $70 to $150 or more. Heavier cords last longer and work with more tools, so one good cord often replaces several cheap ones. Adding a permanent outdoor GFCI outlet through an electrician usually costs a few hundred dollars depending on access.
When to Call a Pro
An extension cord is a temporary connection. If you find yourself running the same cord every day to the garage, patio or workshop, ask a licensed electrician about a new outlet or circuit. Call one as well for scorched outlets, breakers that trip repeatedly, a generator transfer switch, or any outdoor receptacle that lacks GFCI protection. These fixes remove the root problem rather than working around it with a bigger cord.
Frequently Asked Questions
What gauge extension cord do I need for 15 amps?
For a 15-amp load, 14 AWG works up to about 25 feet, 12 AWG suits runs to around 50 feet, and 10 AWG is safer at 100 feet. Always check the cord’s printed amp rating.
Is a lower gauge number thicker or thinner?
Thicker. A 12-gauge cord has heavier copper than a 16-gauge cord and can carry more current with less voltage drop.
Can I use an extension cord with a space heater?
The safe practice, and what nearly every manufacturer requires, is plugging the heater directly into a wall outlet. Heaters draw a heavy load for hours and can overheat cords and power strips.
Is it safe to connect two extension cords together?
It is better to use one cord of the correct length and gauge. Each extra connection adds resistance and a point that can loosen, heat up or get wet.
What cord should I use with a portable generator?
Use an outdoor-rated cord sized for the load and length, often 12 or 10 AWG, so the generator can sit at least 20 feet from the house. Connecting to home wiring needs a transfer switch installed by a licensed electrician.