A shower that drains slow, sprays from the wrong height, or fails inspection traces back to one moment — the rough-in. Getting the shower rough in plumbing right before drywall closes the wall is the single most important step in any bathroom remodel, because correcting a mistake later means tearing out tile and starting over. This guide covers the supply and drain dimensions, the code-required valve heights, the materials that pass inspection in every state, and the step-by-step order of operations that licensed plumbers follow. Whether you are DIYing your own remodel or just verifying a contractor’s work, these are the numbers that matter.
Part of our Bathroom Remodeling & Flooring guide — explore the full guide →
- Key Dimensions to Memorize
- Tools and Materials
- Step One: Lay Out the Drain
- Step Two: Install the P-Trap and Drain Line
- Step Three: Frame and Block the Valve Wall
- Step Four: Run the Supply Lines
- Step Five: Install the Valve and Riser
- Step Six: Pressure Test
- Common Code Failures
- When to Call a Plumber
Key Dimensions to Memorize
Start with the measurements you need.
- Drain location: centered in the shower pan footprint, typically 8 to 12 inches from the back wall on standard 36 by 36 or 36 by 48 pans
- Drain pipe size: 2-inch ABS or PVC required for showers (1.5-inch is for tubs only)
- P-trap depth: bottom of trap arm 2 to 4 inches below the subfloor
- Valve rough-in height: 48 inches off the finished floor for the mixing valve (so the control knob lands at chest height)
- Shower head height: 80 inches off the finished floor for the shower arm penetration
- Hot/cold supply lines: 1/2-inch PEX or copper minimum, 8 inches apart at the valve
These numbers come from the IPC and IRC. Local code may differ — verify with your inspector before cutting any pipe.
Tools and Materials
A typical shower rough-in needs the following.
- 2-inch ABS or PVC pipe and fittings for the drain
- 2-inch P-trap
- 1/2-inch PEX or copper for supply lines
- Pressure-balancing or thermostatic shower valve (code requires one or the other now)
- Shower arm drop-ear elbow (or similar) for the head
- PEX expansion tool or copper torch and solder
- PVC primer and cement
- Pipe straps and silent fasteners
For valves, Delta Multichoice and Moen Posi-Temp are the two most common DIY-friendly cartridges. Both meet ASSE 1016 anti-scald requirements.
Step One: Lay Out the Drain
Locate the drain center based on the shower pan you are using. Pre-fab acrylic pans give exact drain locations in the spec sheet. Custom tile pans drain to a center or linear drain — measure twice.
Cut into the subfloor and floor framing as needed. Maintain joist integrity: never notch more than 1/6 of joist depth, and stay within the middle third of the span when drilling holes (no larger than 1/3 of joist depth). If you have to cut a joist, add sister joists or use a steel header.
Step Two: Install the P-Trap and Drain Line
The P-trap sits directly below the drain. From the trap arm, run the 2-inch drain line at a 1/4-inch-per-foot slope to the nearest 3-inch waste branch or main stack. Glue all PVC joints with primer first, cement second. ABS uses single-step cement.
Test the drain by pouring a gallon of water through it before closing the floor. Confirm the trap holds water and the line drains within 30 seconds.
Step Three: Frame and Block the Valve Wall
Add a horizontal 2×6 or 2×8 block between studs at 48 inches off the finished floor to mount the valve. A second block at 80 inches supports the shower arm elbow. Solid blocking is critical — a valve flopping in the wall is a leak waiting to happen.
Step Four: Run the Supply Lines
Pull hot and cold 1/2-inch PEX or copper from the nearest mains to the valve location. PEX flexes through framing more easily and resists freeze damage better than copper. Use a PEX expansion or crimp tool — Sharkbite push-fittings are not approved for behind-wall splices in most jurisdictions.
At the valve, hot connects to the side marked H, cold to the side marked C. The top outlet feeds the shower head riser. The bottom outlet is for tub spout (cap it for shower-only installs). Some valves have a separate transfer outlet for handheld diverters.
Step Five: Install the Valve and Riser
Mount the valve body to the blocking with screws through the integrated tabs. Check that the depth gauge (the plaster guide) sits flush with the planned finish surface — typically 1/2-inch tile over 1/2-inch backerboard means the gauge sits about 1 inch proud of the framing.
Pipe the supply lines into the valve. From the top outlet, run a 1/2-inch riser up to the drop-ear elbow at 80 inches. Strap the riser to the blocking with copper pipe strap so it does not move when someone tugs on the shower head.
Step Six: Pressure Test
Cap the shower outlet, close the valve, and turn on the building water supply. Pressurize to 50 to 60 psi and watch every joint for 30 minutes. Any drop on the pressure gauge means a leak somewhere. Find it, fix it, and re-test before drywall.
This is the step DIYers most often skip and pros never do. A small leak behind tile becomes a mold disaster six months later.
Common Code Failures
Inspectors fail rough-ins for predictable reasons.
- Wrong drain pipe size (1.5-inch instead of 2-inch)
- Missing pressure-balancing valve (legacy two-handle setups no longer pass)
- Improper trap arm length (too long causes siphoning)
- Missing vent within 5 feet of the trap weir
- Hot on the right side instead of left (code requires hot on left at the valve)
Walk through your work with this list before scheduling the inspector.
When to Call a Plumber
Rough-in for a single shower in an open-frame remodel is reasonable DIY work if you understand local code and pull a permit. Moving a drain location, adding a new vent stack, or tying into cast iron or galvanized waste lines starts to require specialized tools and experience. Expect to pay $1,500 to $4,000 for a full shower rough-in by a licensed plumber depending on accessibility and existing conditions. Cheap insurance compared to the cost of a failed inspection or a wall leak inside a finished bathroom.