Most people searching for the delta 1400 series are standing in front of a dripping shower handle, trying to figure out which cartridge or trim kit to buy. The short answer: in the Delta Monitor family, the 13 and 14 Series do the same job with the same single-handle pressure-balance cartridge, and they differ mainly in how the trim looks. The 17 Series is a different animal, with a dual-function cartridge that gives you separate control over temperature and water volume.
What trips people up is the valve body hidden in the wall. A 1300 or 1400 valve installed before roughly March 2006 takes an older cartridge, while the MultiChoice Universal valve installed after that date takes a newer one, and the two cartridges are not interchangeable. Get the valve age right and almost every other decision falls into place.
- Delta 1400 Series vs 1300 and 1700 at a Glance
- How the 13 and 14 Series Differ
- What the 17 Series Adds
- How to Identify Which Delta Valve You Have
- Tools and Materials for a Cartridge or Trim Swap
- Step by Step: Replacing a 13/14 Series Cartridge
- Scald Safety and Temperature Limits
- Troubleshooting Common Delta Monitor Problems
- General Cost Ranges
- When to Call a Licensed Professional
- Frequently Asked Questions
The sections that follow lay out the differences side by side, explain how to identify what you have, and walk through a cartridge or handle swap so you buy the right part the first time.
Delta 1400 Series vs 1300 and 1700 at a Glance
The comparison table summarizes what Delta lists for each Monitor series. “Series” here refers to the trim and cartridge family, not a different brand of valve. The numbers 1300, 1400 and 1700 are how many homeowners and older parts listings refer to the 13, 14 and 17 Series.
| Feature | Monitor 13 Series | Monitor 14 Series | Monitor 17 Series |
|---|---|---|---|
| Control type | Single handle, pressure balance | Single handle, pressure balance | Dual function: lever for volume, dial for temperature |
| Trim styling | Traditional (Classic look) | More contemporary, matched to several bath collections | Varies by collection |
| Cartridge, valve made after March 2006 | RP46074 (MultiChoice 13/14) | RP46074 (MultiChoice 13/14) | RP46463 (MultiChoice 17 Series) |
| Cartridge, older 1300/1400 valve body | RP19804 | RP19804 | Not compatible with older body |
| Rough-in valve needed for new trim | MultiChoice Universal (R10000 family) | MultiChoice Universal (R10000 family) | MultiChoice Universal (R10000 family) |
| Temperature stability | Pressure balance, roughly plus or minus 3°F | Pressure balance, roughly plus or minus 3°F | Pressure balance, roughly plus or minus 3.6°F |
| Scald limit | Rotational limit stop | Rotational limit stop | Rotational limit stop |
A thermostatic version, often called 17T, also exists. It uses a thermostatic cartridge and sets its temperature limit with a knob instead of a rotational limit stop. Part numbers change over time, so confirm against the parts diagram for your exact trim model before ordering.
How the 13 and 14 Series Differ
Functionally, they do not. Delta describes the 13 and 14 Series as having the same functionality and taking the same valve cartridges. Turn the handle on, rotate it toward hot or cold, and the pressure-balance spool inside the cartridge reacts when someone flushes a toilet or starts the dishwasher, holding the outlet temperature within a few degrees.
The difference is styling. Thirteen Series trims carry a traditional look and sit in the Classic group, while 14 Series trims are drawn to match more contemporary faucet collections. If your sink faucet has a sleek modern profile and you want the shower handle to match, you are probably shopping in the 14 Series.
Because the guts are shared, you can usually swap a 13 Series trim for a 14 Series trim on the same valve body without opening the wall. Delta’s own answers note that 13/14 trim kits work on an existing 1300 valve with its original cartridge, and the same holds for 1400 valves. That makes a cosmetic upgrade one of the cheaper bathroom refreshes available.
What a 14 Series handle swap involves
A delta 1400 series shower handle generally comes off with a small set screw or a snap cap, followed by the escutcheon screws. The new handle and plate go on in reverse. If the new trim kit includes a cartridge, install it only if it matches your valve age. Otherwise keep the original cartridge and use only the cosmetic pieces.
What the 17 Series Adds
The 17 Series moves to two controls on one plate. A lever adjusts how much water flows, and a separate dial sets temperature. You can leave the dial at your preferred setting and simply turn the lever on and off each day, which is the main reason people upgrade.
The catch is the valve body. A 17 Series trim requires the MultiChoice Universal rough-in. On an older 1300 or 1400 valve body, Delta’s guidance is that you can only use 13 or 14 trims without changing the rough-in valve. Moving to 17 on an older shower means opening the wall, cutting out the old body, and installing a new universal valve, which is a plumbing job, not a trim swap.
If your valve is already a MultiChoice Universal from after 2006, a 13 or 14 trim can be upgraded to a 17 by swapping the cartridge and trim. That flexibility was the point of the universal design.
How to Identify Which Delta Valve You Have
Before buying anything, figure out three things: the trim series, the valve age, and the cartridge in the wall.
- Look at the handle. One lever that both starts flow and sets temperature means 13 or 14. A lever plus a separate dial means 17 or 17T.
- Estimate the install date. Original showers from homes built before 2006 are likely to have the older body. Remodels after 2006 often have the universal valve.
- Pull the cartridge and read it. Older RP19804 cartridges are commonly described as blue and white, newer RP46074 cartridges as gray and tan. Color is a hint only, so match the part number or shape against the parts listing.
- Check the valve body. With the trim off, some bodies show markings cast or stamped into the brass. A photo helps a supply house or the manufacturer’s support line confirm compatibility.
Tools and Materials for a Cartridge or Trim Swap
- Phillips and flat screwdrivers, plus a small hex key for set-screw handles
- Adjustable wrench or the bonnet nut wrench size listed in your parts diagram
- A shower valve cartridge puller if the old cartridge is stuck from mineral buildup
- Silicone-based plumber’s grease (rated for potable water)
- Replacement cartridge or trim kit matched to your valve age
- Towel to cover the drain so small screws do not disappear
- Vinegar and a soft brush for scale on the valve body
Step by Step: Replacing a 13/14 Series Cartridge
- Shut off the water. Some valves have built-in stops behind the trim. If yours does not, close the main and open a low faucet to relieve pressure.
- Remove the handle and escutcheon. Pop the cap or loosen the set screw, pull the handle, then unscrew the plate.
- Remove the bonnet nut or retaining clip, depending on the valve generation.
- Pull the cartridge. Wiggle it straight out. If it refuses, use a puller rather than prying, which can scar the brass.
- Clean the body. Wipe out scale and debris, and check that the seats and springs (if present) are not damaged.
- Install the new cartridge with a light coat of grease on the O-rings, oriented with hot on the correct side per the instructions.
- Reassemble, then set the rotational limit stop. Turn the water back on, run the shower fully hot, and adjust the stop so maximum temperature is comfortable and safe.
- Check for leaks at the plate and showerhead after a few minutes of running.
Plan on 30 to 90 minutes for a straightforward cartridge swap. A seized cartridge on an older valve can stretch that well past two hours.
Scald Safety and Temperature Limits
Pressure balance protects against sudden spikes when pressure changes, but it does not cap how hot the water can get. That is what the rotational limit stop is for, and it should be set every time you replace a cartridge. Many people skip it and end up with a valve that can deliver dangerously hot water to a child or older adult.
Set your water heater to a safe temperature as well; 120°F is a common anti-scald target. Before any work on the heater, turn off its power or set gas to pilot, let the tank cool, and follow the label. When working on the valve, always shut off supply and relieve pressure before loosening any nut.
Troubleshooting Common Delta Monitor Problems
- Drip from the showerhead after shutoff: worn seats and springs or a worn cartridge. On older bodies, seats and springs are often the fix; on newer ones, the cartridge is usually the culprit.
- Water never gets hot: the rotational limit stop is set too low, or the cartridge was installed rotated. Re-check orientation and the stop.
- Hot and cold reversed: the cartridge was installed upside down or the supplies are reversed. Many cartridges can be rotated to correct this.
- Handle stiff: mineral buildup. Clean and regrease, or replace the cartridge.
- Low flow on one side only: debris at the inlet or a partly closed stop.
- New 17 trim will not fit: the valve body is an older 1300/1400, which needs a new rough-in.
General Cost Ranges
A replacement cartridge typically runs from about $30 to $150 depending on series, with the 17 Series cartridge at the upper end. A full 13 or 14 trim kit commonly lands in the $100 to $300 range depending on finish. A 17 Series trim generally costs more. Hiring a plumber to swap a cartridge often runs $150 to $350. Replacing the valve body to convert an old 1300 or 1400 to the universal valve can run $400 to $1,200 or more, especially if tile has to be cut and patched.
When to Call a Licensed Professional
A cartridge or trim swap is a reasonable DIY job. Replacing the valve body is not, for most homeowners: it means cutting into the wall, soldering or crimping supply connections, and pressure-testing before closing up. Many areas require a permit for valve replacement and expect the work to be done by a licensed plumber. Call one if the valve is corroded, if you cannot shut off the water reliably, if the wall shows signs of leaks, or if you plan to convert an older 1300 or 1400 to the 17 Series. A licensed plumber can also confirm your water heater setting and the anti-scald performance of the finished valve.
Frequently Asked Questions
Are Delta 1300 and 1400 series cartridges the same?
Yes. The 13 and 14 Series share cartridges. Valves made before about March 2006 use the older RP19804, and MultiChoice Universal valves made after use RP46074. The two cartridges are not interchangeable.
Can I put a 17 Series trim on my 1400 valve?
Only if the valve is a MultiChoice Universal body. An older 1400 valve body accepts 13 or 14 trims only, so a 17 upgrade requires a new rough-in valve.
What is the difference between the 17 and 17T Series?
The 17 uses a pressure-balance cartridge, while 17T uses a thermostatic cartridge. Both separate volume from temperature, and 17T sets its temperature limit with a knob.
How do I change a delta 1400 series shower handle?
Remove the cap or set screw, pull off the handle, then remove the escutcheon screws. Install the new trim in reverse and keep the existing cartridge if it matches your valve age.
Why is my Delta shower not getting hot enough?
The rotational limit stop is often set too low after a repair. Adjust it carefully, and keep the water heater at a safe setting such as 120°F.