R38 Insulation Thickness (Plus R19, R30 and R49 Chart)

R38 Insulation Thickness (Plus R19, R30 and R49 Chart)

The r38 insulation thickness you need depends on the material, not the R-value alone. R38 fiberglass batts are about 12 inches thick, high-density R38 batts made for tight rafter bays are roughly 10 to 10.25 inches, blown fiberglass usually needs 13 to 17 inches depending on the product, and blown cellulose reaches R38 at about 10 to 12 inches once it settles. That spread surprises people who assume one R-value equals one depth.

The difference comes from R-value per inch. Each material traps air differently, so a 12 inch layer of one product can outperform or underperform a 12 inch layer of another. The chart and explanations that follow give typical depths for R19, R30, R38 and R49, how much to add for settling, and how to check what is already in your attic.

R38 Insulation Thickness by Material

R-value measures resistance to heat flow. Higher is better, and building energy guidelines for much of the US recommend R38 to R60 in attic floors depending on climate zone. Here is how the common attic materials compare at R38:

  • Standard fiberglass batts: about 12 inches. These are the most common rolls sold for attic floors.
  • High-density fiberglass batts: about 10 to 10.25 inches. Designed for cathedral ceilings and 2×12 rafters where depth is limited.
  • Blown (loose-fill) fiberglass: roughly 13 to 17 inches. R-value per inch varies widely by product, from about 2.2 to 2.9.
  • Blown cellulose: roughly 10 to 12 inches settled depth, at about 3.2 to 3.8 per inch.
  • Mineral wool batts: about 3.0 to 3.3 per inch, so roughly 11.5 to 12.5 inches for R38, though they are more often used in walls.

For loose-fill, always trust the coverage chart printed on the bag. It lists the installed thickness, the minimum settled thickness and the number of bags per 1,000 square feet for each R-value. Those numbers are tested for that specific product and are what an inspector or energy auditor will check.

Insulation Thickness Chart: R19, R30, R38 and R49

These are typical ranges. Your product’s label governs.

R-value Fiberglass batt Blown fiberglass Blown cellulose (settled)
R19 6 to 6.25 in 7 to 8.5 in 5 to 6 in
R30 9.5 to 10 in 10.5 to 13.5 in 8 to 9.5 in
R38 10.25 to 12 in 13 to 17 in 10 to 12 in
R49 14 to 16 in 17 to 22 in 13 to 15 in

R19 insulation thickness

R19 insulation thickness for a standard batt is about 6.25 inches, sized for 2×6 framing. Compressing an R19 batt into a 2×6 wall (5.5 inches deep) lowers its effective value to around R18, which is still acceptable. R19 is common in floors over crawlspaces and in 2×6 exterior walls, but it falls well short of modern attic recommendations.

R30 insulation thickness

R30 insulation thickness is roughly 9.5 to 10 inches for standard batts, with high-density R30 versions around 8.25 inches for 2×10 rafters. Many older homes have R30 or less in the attic, so adding a second layer to reach R49 or higher is a common upgrade.

R49 thickness

R49 batts are typically about 14 to 16 inches, often installed as two layers, for example R30 plus R19 laid perpendicular. Blown products reach R49 faster and with fewer gaps, which is why most contractors blow in insulation for deep attic retrofits.

Choosing a Material for R38

When you plan for a specific r38 insulation thickness, the attic itself often decides the material. An open attic floor with plenty of headroom suits any option, and blown products cover around wiring, junction boxes and irregular framing with fewer gaps than cut batts. A shallow attic or a cathedral ceiling favors high-density batts or a higher R-per-inch material, since every inch counts.

Fiberglass batts are clean to handle in small areas, easy to lift later for repairs and simple to cut around obstacles. They also tend to leave gaps at joists and wiring unless you cut them carefully, and those gaps can reduce whole-attic performance noticeably. Blown fiberglass resists moisture and settles little, but it needs more depth for the same R-value. Cellulose packs more R-value into each inch and does a good job filling small voids, though it is heavier and settles more. For a typical retrofit over existing insulation, many contractors favor blown cellulose or blown fiberglass, and save batts for knee walls, floors over garages and small sections where a blower is impractical.

Settling: Why Installed Depth Is Higher

Loose-fill insulation settles after installation. Cellulose settles the most, commonly 13 to 20 percent over the first months, so it is blown deeper than the target and allowed to compress. Blown fiberglass settles very little, often only a few percent. Batts do not settle significantly, but they lose R-value when compressed by stored boxes, flooring or ductwork pressing on them.

Bag charts list two numbers: initial installed thickness and minimum settled thickness. If your target is an R38 insulation thickness with cellulose, you might install 12 to 13 inches so that it settles to around 10.5 inches or more. Always blow to the initial thickness on the bag, not the settled thickness, or you will end up short of your target.

How to Measure Existing Attic Insulation

  1. Gear up: wear a long-sleeve shirt, gloves, eye protection and a disposable N95 or better respirator. Attic dust and fibers irritate skin and lungs.
  2. Move safely: step only on joists or a board laid across them. Drywall ceilings will not support your weight.
  3. Measure several spots: push a ruler straight down to the ceiling drywall in at least five places, away from eaves and near the center. Average the readings.
  4. Identify the material: pink, yellow or white fluffy fibers are usually fiberglass. Gray, paper-like flakes are cellulose. Gray-brown or shiny pebbles may be vermiculite, which can contain asbestos; do not disturb it and have it tested.
  5. Calculate R-value: multiply the average depth by the per-inch value for the material. Ten inches of older fiberglass at about 2.5 per inch is about R25, well short of R38.

Adding Insulation to Reach R38 or More

Most homes can add insulation on top of what is already there, as long as the existing layer is dry and clean. Fiberglass batt insulation is easy to roll out by hand. Use unfaced batts for the second layer, run them perpendicular to the joists to cover the tops of the framing, and never add a second vapor retarder on top of existing insulation, which can trap moisture.

Blown insulation gives the most even coverage. Many home centers lend a blower with a bag purchase. Before blowing, mark target depth with rulers stapled to joists at several spots so you can see when you have hit the bag chart thickness.

Prep steps first

  • Air seal: caulk and foam gaps around wiring holes, plumbing stacks, top plates and the attic hatch. Air sealing often matters as much as R-value.
  • Protect ventilation: install baffles at the eaves so insulation does not block soffit vents.
  • Light fixtures: recessed lights must be IC rated to be covered. Otherwise keep insulation at least 3 inches away or build a fire-rated cover box.
  • Chimneys and flues: keep insulation clear by the distance specified by local code, usually with a metal dam, and use noncombustible material around them.
  • Wiring: knob-and-tube wiring should not be buried in insulation. Have an electrician evaluate it first.

Troubleshooting Common Insulation Problems

Uneven depth: loose-fill often piles up near the hatch and thins near the eaves. Rake it level or add more where it is thin. Depth rulers make gaps obvious.

Compressed batts: boxes, plywood or ductwork laid on batts compress them. Raise any attic storage platform on risers so the insulation keeps its full loft.

Wet or stained insulation: moisture means a roof leak, bathroom fan venting into the attic or condensation. Fix the source and replace soaked insulation, since wet fiberglass and cellulose lose much of their R-value.

Cold rooms despite deep insulation: air leaks may be the cause. A blower door test from an energy auditor finds them quickly.

Cost Ranges

DIY fiberglass batts or blown insulation for an average attic usually runs a few hundred dollars to around a thousand in materials. Professional installation of blown cellulose or fiberglass to R38 or R49 commonly costs roughly $1 to $2.50 per square foot of attic floor, more if old insulation must be removed or extensive air sealing is needed. Utility rebates and energy efficiency incentives often offset part of the cost, so check before you buy.

When to Call a Pro

Hire an insulation contractor if the attic is cramped or hot, if you find vermiculite, mold or pest damage, or if you want a blower door test and air sealing done together with insulation. Call a licensed electrician for knob-and-tube wiring or non-IC recessed lights, and a roofer for any leak before covering the area. Professionals with the right blowing equipment can also reach the eaves evenly, where DIY coverage often falls short.

Frequently Asked Questions

How thick is R38 insulation?

Standard R38 fiberglass batts are about 12 inches thick, and high-density R38 batts about 10 to 10.25 inches. Blown fiberglass needs roughly 13 to 17 inches, and blown cellulose about 10 to 12 inches settled.

Will R38 batts fit in 2×10 rafters?

Standard 12 inch batts will not fit without compression. High-density R38 batts about 10.25 inches thick are designed for deeper rafters, and in 2×10 bays you may need to fur down the rafters or use rigid foam to reach R38 while leaving an air channel.

Is R38 enough for my attic?

R38 is the minimum recommended in warmer parts of the US. In colder climate zones, R49 to R60 is recommended, so many homeowners blow insulation deeper to reach those levels.

Can I put new insulation on top of old insulation?

Yes, if the existing insulation is dry, free of mold and not vermiculite. Use unfaced batts or loose-fill on top, and do not add a second vapor retarder.

How much does blown cellulose settle?

Cellulose typically settles about 13 to 20 percent. Blow it to the initial installed depth listed on the bag so it settles to at least the minimum thickness for your target R-value.

How thick is R38 spray foam insulation?

Closed-cell spray foam reaches R38 at roughly 5.5 to 6.5 inches, since it delivers about R6 to R7 per inch. Open-cell spray foam rates around R3.5 to R3.8 per inch, so it needs about 10 to 11 inches for R38. Spray foam also air-seals as it insulates, which is why it is often used in cathedral ceilings and rafters where depth is limited. Check the product’s rated R-value per inch.

How thick is R38 rigid foam insulation?

It depends on the foam. Polyiso at about R6 per inch needs roughly 6.5 inches, XPS at R5 per inch about 7.5 to 8 inches, and EPS at about R4 per inch roughly 9.5 inches. Rigid foam is usually installed in several staggered layers with taped seams, often above roof decks or under a ceiling, and exposed foam indoors needs a code-approved thermal barrier such as drywall.

Will R38 batts fit in 2×12 joists?

Yes, on an open attic floor. A 2×12 is about 11.25 inches deep, so standard 12 inch R38 batts rise slightly above the joists, which is fine and helps cover the framing. In enclosed rafter bays or cathedral ceilings, use high-density R38 batts about 10.25 inches thick so there is room for a ventilation channel above the insulation when the roof design requires one.